542 research outputs found

    Beam instrumentation for the Tevatron Collider

    Full text link
    The Tevatron in Collider Run II (2001-present) is operating with six times more bunches and many times higher beam intensities and luminosities than in Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and the never-ending luminosity upgrade campaign. We present the overall picture of the Tevatron diagnostics development for Run II, outline machine needs for new instrumentation, present several notable examples that led to Tevatron performance improvements, and discuss the lessons for future colliders

    Beam Test Results of the BTeV Silicon Pixel Detector

    Get PDF
    The results of the BTeV silicon pixel detector beam test carried out at Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has been studied as a function of track inclination, sensor bias, and readout threshold.Comment: 8 pages of text, 8 figures, Proceedings paper of Pixel 2000: International Workshop on Semiconductor Pixel Detectors for Particles and X-Rays, Genova, June 5-8, 200

    Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Genetically engineered mouse models of human cardiovascular disease provide an opportunity to understand critical pathophysiological mechanisms. Cardiovascular magnetic resonance (CMR) provides precise reproducible assessment of cardiac structure and function, but, in contrast to echocardiography, requires that the animal be immobilized during image acquisition. General anesthetic regimens yield satisfactory images, but have the potential to significantly perturb cardiac function. The purpose of this study was to assess the effects of general anesthesia and a new deep sedation regimen, respectively, on cardiac function in mice as determined by CMR, and to compare them to results obtained in mildly sedated conscious mice by echocardiography.</p> <p>Results</p> <p>In 6 mildly sedated normal conscious mice assessed by echo, heart rate was 615 ± 25 min<sup>-1 </sup>(mean ± SE) and left ventricular ejection fraction (LVEF) was 0.94 ± 0.01. In the CMR studies of normal mice, heart rate was slightly lower during deep sedation with morphine/midazolam (583 ± 30 min<sup>-1</sup>), but the difference was not statistically significant. General anesthesia with 1% inhaled isoflurane significantly depressed heart rate (468 ± 7 min<sup>-1</sup>, p < 0.05 vs. conscious sedation). In 6 additional mice with ischemic LV failure, trends in heart rate were similar, but not statistically significant. In normal mice, deep sedation depressed LVEF (0.79 ± 0.04, p < 0.05 compared to light sedation), but to a significantly lesser extent than general anesthesia (0.60 ± 0.04, p < 0.05 vs. deep sedation).</p> <p>In mice with ischemic LV failure, ejection fraction measurements were comparable when performed during light sedation, deep sedation, and general anesthesia, respectively. Contrast-to-noise ratios were similar during deep sedation and during general anesthesia, indicating comparable image quality. Left ventricular mass measurements made by CMR during deep sedation were nearly identical to those made during general anesthesia (r<sup>2 </sup>= 0.99, mean absolute difference < 4%), indicating equivalent quantitative accuracy obtained with the two methods. The imaging procedures were well-tolerated in all mice.</p> <p>Conclusion</p> <p>In mice with normal cardiac function, CMR during deep sedation causes significantly less depression of heart rate and ejection fraction than imaging during general anesthesia with isoflurane. In mice with heart failure, the sedation/anesthesia regimen had no clear impact on cardiac function. Deep sedation and general anesthesia produced CMR with comparable image quality and quantitative accuracy.</p

    Beam Test of BTeV Pixel Detectors

    Full text link
    The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensor-readout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.Comment: 7 pages, 5 figures, Invited talk given by J.C. Wang at "Vertex 2000, 9th International Workshop on Vertex Detectors", Michigan, Sept 10-15, 2000. To be published in NIM

    Performance of prototype BTeV silicon pixel detectors in a high energy pion beam

    Get PDF
    The silicon pixel vertex detector is a key element of the BTeV spectrometer. Sensors bump-bonded to prototype front-end devices were tested in a high energy pion beam at Fermilab. The spatial resolution and occupancies as a function of the pion incident angle were measured for various sensor-readout combinations. The data are compared with predictions from our Monte Carlo simulation and very good agreement is found.Comment: 24 pages, 20 figure

    Lung cancer, genetic predisposition and smoking : the Nordic Twin Study of Cancer

    Get PDF
    Background We aimed to disentangle genetic and environmental causes in lung cancer while considering smoking status. Methods Four Nordic twin cohorts (43 512 monozygotic (MZ) and 71 895 same sex dizygotic (DZ) twin individuals) had smoking data before cancer diagnosis. We used time-to-event analyses accounting for censoring and competing risk of death to estimate incidence, concordance risk and heritability of liability to develop lung cancer by smoking status. Results During a median of 28.5 years of follow-up, we recorded 1508 incident lung cancers. Of the 30 MZ and 28 DZ pairs concordant for lung cancer, nearly all were current smokers at baseline and only one concordant pair was seen among never smokers. Among ever smokers, the case-wise concordance of lung cancer, that is the risk before a certain age conditional on lung cancer in the co-twin before that age, was significantly increased compared with the cumulative incidence for both MZ and DZ pairs. This ratio, the relative recurrence risk, significantly decreased by age for MZ but was constant for DZ pairs. Heritability of lung cancer was 0.41 (95% CI 0.26 to 0.56) for currently smoking and 0.37 (95% CI 0.25 to 0.49) for ever smoking pairs. Among smoking discordant pairs, the pairwise HR for lung cancer of the ever smoker twin compared to the never smoker co-twin was 5.4 (95% CI 2.1 to 14.0) in MZ pairs and 5.0 (95% CI 3.2 to 7.9) in DZ pairs. Conclusions The contribution of familial effects appears to decrease by age. The discordant pair analysis confirms that smoking causes lung cancer.Peer reviewe

    Observation of the Dynamic Beta Effect at CESR with CLEO

    Get PDF
    Using the silicon strip detector of the CLEO experiment operating at the Cornell Electron-positron Storage Ring (CESR), we have observed that the horizontal size of the luminous region decreases in the presence of the beam-beam interaction from what is expected without the beam-beam interaction. The dependence on the bunch current agrees with the prediction of the dynamic beta effect. This is the first direct observation of the effect.Comment: 9 page uuencoded postscript file, postscritp file also available through http://w4.lns.cornell.edu/public/CLNS, submitted to Phys. Rev.

    Theoretical Overview: The New Mesons

    Full text link
    After commenting on the state of contemporary hadronic physics and spectroscopy, I highlight four areas where the action is: searching for the relevant degrees of freedom, mesons with beauty and charm, chiral symmetry and the D_{sJ} levels, and X(3872) and the lost tribes of charmonium.Comment: 10 pages, uses jpconf.cls; talk at First Meeting of the APS Topical Group on Hadronic Physic
    • …
    corecore